[SC7232]  RS485 interface LED displays soil moisture temperature controller


  Soil moisture temperature controller, also known as soil temperature and humidity controller, soil temperature and humidity controller, is mainly composed of two parts: controller instrument, soil moisture sensor. The controller has high reliability and stability, It meets the needs of users in many aspects. The product has the characteristics of simple operation, high precision, low cost, etc. It can be widely used in various soil temperature control places. To facilitate real-time monitoring of equipment operation and control status, the device has designed RS485 communication interface, which is convenient for users. It is connected with computer or network. Due to the widely used MODBUS-RTU communication protocol, the product is easy to integrate into PLC, man-machine interface, configuration software and other equipment or systems. Users can realize control parameters and data according to communication protocol. Query or set. The product is suitable for scientific experiments, water-saving irrigation, greenhouses, flowers and vegetables, grassland pastures, soil rapid measurement, plant cultivation, sewage treatment and measurement and control of various water content of particulate matter.

Technical Parameters

Technical parameter Parameter value
Brand SONBEST
Moisture measuring range 0~100%
Moisture measuring accuracy ±3% @25℃
Moisture Temperature range -30℃~80℃
Moisture Temperature accuracy ±0.5℃ @25℃
Communication Interface RS485
Default baud rate 9600 8 n 1
Power AC185~265V 1A
Dimensions 77mm×77mm×110mm
Running temperature -40~80°C
Working humidity 5%RH~90%RH

How to wiring?

SC7232

SC7232

SC7232

Why choose this product?

SC7232

How to use?

SC7232

SC7232

SC7232

Communication Protocol

    The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device is shipped, the default baud rate is 9600, 8, n, 1
1. Read Data (Function id 0x03)
    Inquiry frame (hexadecimal), sending example: Query 1# device 1 data, the host computer sends the command:01 03 00 00 00 02 C4 0B .
Device ID Function id Start Address Data Length CRC16
01 03 00 00 00 02 C4 0B
    For the correct query frame, the device will respond with data:01 03 04 00 7A 00 00 DB EA , the response format is parsed as follows:
Device ID Function id Data Length 数据1 数据2 Check Code
01 03 04 00 79 00 7A DB EA
    Data Description: The data in the command is hexadecimal. Take data 1 as an example. 00 79 is converted to a decimal value of 121. If the data magnification is 100, the actual value is 121/100=1.21. Others and so on.
2. Data Address Table
Address Start Address Description Data type Value range
40001 00 00 1#soil Moistureregister Read only 0~65535
40002 00 01 2#soil Moistureregister Read only 0~65535
40101 00 64 model code read/write 0~65535
40102 00 65 total points read/write 1~20
40103 00 66 Device ID read/write 1~249
40104 00 67 baud rate read/write 0~6
40105 00 68 mode read/write 1~4
40106 00 69 protocol read/write 1~10
3 read and modify device address
(1) Read or query device address
    If you don"t know the current device address and there is only one device on the bus, you can use the command FA 03 00 64 00 02 90 5F Query device address.
Device ID Function id Start Address Data Length CRC16
FA 03 00 64 00 02 90 5F
    FA is 250 for the general address. When you don"t know the address, you can use 250 to get the real device address, 00 64 is the device model register.
    For the correct query command, the device will respond, for example the response data is: 01 03 02 07 12 3A 79, the format of which is as shown in the following table:
Device ID Function id Start Address Model Code CRC16
01 03 02 55 3C 00 01 3A 79
    Response should be in the data, the first byte 01 indicates that the real address of the current device is, 55 3C converted to decimal 20182 indicates that the current device main model is 21820, the last two bytes 00 01 Indicates that the device has a status quantity.
(2)Change device address
    For example, if the current device address is 1, we want to change to 02, the command is:01 06 00 66 00 02 E8 14 .
Device ID Function id Start Address Destination CRC16
01 06 00 66 00 02 E8 14
    After the change is successful, the device will return information: 02 06 00 66 00 02 E8 27 , its format is parsed as shown in the following table:
Device ID Function id Start Address Destination CRC16
01 06 00 66 00 02 E8 27
    Response should be in the data, after the modification is successful, the first byte is the new device address. After the general device address is changed, it will take effect immediately. At this time, the user needs to change the query command of the software at the same time.
4 Read and Modify Baud Rate
(1) Read baud rate
    The device default factory baud rate is 9600. If you need to change it, you can change it according to the following table and the corresponding communication protocol. For example, read the current device"s baud rate ID, the command is:01 03 00 67 00 01 35 D5 , its format is parsed as follows.
Device ID Function id Start Address Data Length CRC16
01 03 00 67 00 01 35 D5
    Read the baud rate encoding of the current device. Baud rate encoding: 1 is 2400; 2 is 4800; 3 is 9600; 4 is 19200; 5 is 38400; 6 is 115200.
    For the correct query command, the device will respond, for example the response data is: 01 03 02 00 03 F8 45, the format of which is as shown in the following table:
Device ID Function id Data Length Rate ID CRC16
01 03 02 00 03 F8 45
    coded according to baud rate, 03 is 9600, ie the current device has a baud rate of 9600.
(2)Change the baud rate
    For example, changing the baud rate from 9600 to 38400, ie changing the code from 3 to 5, the command is: 01 06 00 67 00 05 F8 1601 03 00 66 00 01 64 15 .
Device ID Function id Start Address Target Baud Rate CRC16
01 03 00 66 00 01 64 15
    Change the baud rate from 9600 to 38400, changing the code from 3 to 5. The new baud rate will take effect immediately, at which point the device will lose its response and the baud rate of the device should be queried accordingly. Modified.
5 Read Correction Value
(1) Read Correction Value
    When there is an error between the data and the reference standard, we can reduce the display error by adjusting the correction value. The correction difference can be modified to be plus or minus 1000, that is, the value range is 0-1000 or 64535 -65535. For example, when the display value is too small, we can correct it by adding 100. The command is: 01 03 00 6B 00 01 F5 D6 . In the command 100 is hex 0x64 If you need to reduce, you can set a negative value, such as -100, corresponding to the hexadecimal value of FF 9C, which is calculated as 100-65535=65435, and then converted to hexadecimal to 0x FF 9C. The correction value starts from 00 6B. We take the first parameter as an example. The correction value is read and modified in the same way for multiple parameters.
Device ID Function id Start Address Data Length CRC16
01 03 00 6B 00 01 F5 D6
    For the correct query command, the device will respond, for example the response data is: 01 03 02 00 64 B9 AF, the format of which is as shown in the following table:
Device ID Function id Data Length Data value CRC16
01 03 02 00 64 B9 AF
    In the response data, the first byte 01 indicates the real address of the current device, and 00 6B is the first state quantity correction value register. If the device has multiple parameters, other parameters operate in this way. The same, the general temperature, humidity have this parameter, the light generally does not have this item.
(2)Change correction value
    For example, the current state quantity is too small, we want to add 1 to its true value, and the current value plus 100 correction operation command is:01 06 00 6B 00 64 F9 FD .
Device ID Function id Start Address Destination CRC16
01 06 00 6B 00 64 F9 FD
    After the operation is successful, the device will return information: 01 06 00 6B 00 64 F9 FD, the parameters take effect immediately after successful change.

 