Technical Parameters

Technical parameterParameter value
BrandSONBEST
Temperature measuring range-30℃~80℃
Temperature measuring accuracy±0.5℃ @25℃
PM2.5 range0~999ug/m3
PM2.5 accuracy±15% or ±10ug/m3 max @25℃
PM10 range0~999ug/m3
PM10 accuracy±15% or ±35ug/m3 max @25℃
Illuminance measuring range0~65535Lux
Illuminance allow deviation±7%
Repeatability test±5%
Illuminance detection chipImport digital
Wavelength range380nm~730nm
Communication InterfaceRS485
Default baud rate9600 8 n 1
PowerDC5~24V 1A
Running temperature-30~85℃
Working humidity5%RH~90%RH

Product Size

SD8835B

Wiring instructions

Why choose this product?

SD8835B SD8835B SD8835B

Application solution

SD8835B

How to use?

SD8835B

Product List

SD8835B

Pictures

SD8835B

Communication Protocol

    The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the module or NON-Recorder default baud rate is 9600,8,n,1 ,but data recorder default baud rate is 115200 .
1. Read data (function code 0x03)
    Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 05 85 C9 .
Address Function Code Start Address Data Length Check Code
010300 0000 0585 C9
    For the correct query frame, the device will respond with data: 01 03 0A 00 7D 00 00 00 00 00 00 00 00 19 E4 , response format:
Address Function Code LengthData 1Data 2Data 3Data 4Data 5Check Code
0103 0A00 7900 7A00 7B00 7C00 7D 19 E4
    Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
2. Common data address table
Configuration Address Register Address Register Description Data Type Value Range
4000100 00temperatureRead Only0~65535
4000200 01humidityRead Only0~65535
4000300 02PM2.5Read Only0~65535
4000400 03PM10Read Only0~65535
4000500 04IlluminanceRead Only0~65535
4010100 64Model CodeRead/Write0~65535
4010200 65 total number of measuring points read/write 1~20
4010300 66device addressread/write1~249
4010400 67baud rateread/write0~6
4010500 68communication moderead/write1~4
4010600 69protocol typeread/write1~10