[SM1212B-12]  I2C interface 12 channel SHT20 temperature and humidity sensor acquisition module

SM1212B-12 SM1212B-12 SM1212B-12

Technical Parameters

Technical parameterParameter value
BrandSONBEST
Temperature measuring range-30℃~80℃
Temperature measuring accuracy±0.5℃ @25℃
Support sensorSHT20
Channels12
Input busIIC
Humidity measuring range0~100%RH
Humidity accuracy±3%RH @25℃
Communication InterfaceRS485
Default baud rate9600 8 n 1
PowerDC9~24V 1A
Running temperature-30~85℃

Product Size

SM1212B-12 SM1212B-12 SM1212B-12

Wiring instructions

Why choose this product?

SM1212B-12

Why choose this product?

SM1212B-12 SM1212B-12 SM1212B-12

How to use?

SM1212B-12

Application solution

SM1212B-12 SM1212B-12

Product List

SM1212B-12

Pictures

SM1212B-12 SM1212B-12

Communication Protocol

    The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the module or NON-Recorder default baud rate is 9600,8,n,1 ,but data recorder default baud rate is 115200 .
1. Read data (function code 0x03)
    Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 0C 45 CF .
Address Function Code Start Address Data Length Check Code
010300 0000 0C45 CF
    For the correct query frame, the device will respond with data: 01 03 18 00 79 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A5 E8 , response format:
Address Function Code LengthData 1Data 2Data 3Data 4Data 5Data 6Data ...Data 23Data 24Check Code0103 18
00 7900 7A00 7B00 7C00 7D00 7E............00 7900 79 A5 E8
    Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
2. Common data address table
Configuration Address Register Address Register Description Data Type Value Range
4000100 001#temperature registerRead Only0~65535
4000200 012#humidity registerRead Only0~65535
4000300 023#temperature registerRead Only0~65535
4000400 034#humidity registerRead Only0~65535
4000500 045#temperature registerRead Only0~65535
4000600 056#humidity registerRead Only0~65535
...............
4002300 1623#temperature registerRead Only0~65535
4002400 1724#humidity registerRead Only0~65535
4010100 64Model CodeRead/Write0~65535
4010200 65 total number of measuring points read/write 1~20
4010300 66device addressread/write1~249
4010400 67baud rateread/write0~6
4010500 68communication moderead/write1~4
4010600 69protocol typeread/write1~10


 Online shop 

 Contact Online 

Email: sale@sonbest.com

TYPE: SM1212B-12

WeChat: 13918126020

SKYPE: SOOBUU

Phone: 021-51083595

QQ1: 71182854 QQ2:613035997