Technical Parameters
Technical parameter | Parameter value |
Brand | SONBEST |
Smoke measuring range | 0~5000ppm |
Smoke allow deviation | ±7% |
Smoke Repeatability test | ±5% |
Smoke detection chip | Import digital |
Temperature characteristics | ±0.5%/℃ |
Temperature measuring range | -30℃~80℃ |
Temperature measuring accuracy | ±0.5℃ @25℃ |
PM2.5 range | 0~999ug/m3 |
PM2.5 accuracy | ±15% or ±10ug/m3 max @25℃ |
PM10 range | 0~999ug/m3 |
PM10 accuracy | ±15% or ±35ug/m3 max @25℃ |
Communication Interface | RS485 |
Default baud rate | 9600 8 n 1 |
Power | DC6~24V 1A |
Running temperature | -25~80°C |
Working humidity | 5%RH~90%RH |
Wiring instructions
Any incorrect wiring can cause irreversible damage to the product. Please carefully wire the cable as follows in the case of power failure, and then connect the cable to confirm the correctness and then use it again.ID | Core color | Identification | Note |
1 | Red | V+ | Power + |
2 | Green | V- | Power - |
3 | Yellow | A+ | RS485 A+ |
4 | Blue | B- | RS485 B- |
Communication Protocol
The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the default baud rate is 9600,8,n,1 .1. Read data (function code 0x03)
Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 08 44 0C .
Address | Function Code | Start Address | Data Length | Check Code |
01 | 03 | 00 00 | 00 08 | 44 0C |
Address | Function Code | Length | Data 1 | Data 2 | Data 3 | Data 4 | Data 5 | Data 6 | Data 7 | Data 8 | Check Code |
01 | 03 | 10 | 00 79 | 00 7A | 00 7B | 00 7C | 00 7D | 00 7E | 00 7F | 00 80 | 64 39 |
2. Common data address table
Configuration Address | Register Address | Register Description | Data Type | Value Range |
40001 | 00 00 | conductivity | Read Only | 0~65535 |
40002 | 00 01 | temperature | Read Only | 0~65535 |
40003 | 00 02 | humidity | Read Only | 0~65535 |
40004 | 00 03 | CO2 | Read Only | 0~65535 |
40005 | 00 04 | CO | Read Only | 0~65535 |
40006 | 00 05 | PM2.5 | Read Only | 0~65535 |
40007 | 00 06 | PM10 | Read Only | 0~65535 |
40008 | 00 07 | TVUC | Read Only | 0~65535 |
40101 | 00 64 | Model Code | Read/Write | 0~65535 |
40102 | 00 65 | total number of measuring points | read/write | 1~20 |
40103 | 00 66 | device address | read/write | 1~249 |
40104 | 00 67 | baud rate | read/write | 0~6 |
40105 | 00 68 | communication mode | read/write | 1~4 |
40106 | 00 69 | protocol type | read/write | 1~10 |