    SM1200B-160采用工业通用标准RS485总线 MODBUS-RTU协议接口,方便接入PLC,DCS等各种仪表或系统,用于监测温度等状态量。内部使用了较高精度的传感内核及相关器件,确保产品具有较高的可靠性与卓越的长期稳定性, 可定制RS232、RS485、CAN、4-20mA、DC0~5V/10V、ZIGBEE、Lora、WIFI、GPRS、NB-IOT等多种输出方式。

技术参数

技术参数参数值
品牌SONBEST/搜博
温度测量范围-55℃~125℃
温度测量精度±0.5℃ @25℃
支持温度芯片DS18B20
传感器接线方式三线制
通道数10通道
每通道支持1-16个温度点
支持测点总数160个
地址设置方式拔码开关
通讯接口RS485
默认波特率9600 8 n 1
供电电源DC9~24V 1A
运行环境温度-40~80°C
运行环境湿度5%RH~90%RH

外形尺寸

SM1200B-160

产品接线

SM1200B-160

SM1200B-160

特色与细节

SM1200B-160

SM1200B-160

SM1200B-160

SM1200B-160

应用方案

SM1200B-160

SM1200B-160

典型应用

SM1200B-160

RS485型:通讯协议

    产品使用RS485 MODBUS-RTU标准协议格式,所有操作或回复命令都为16进制数据。设备出厂时默认设备地址为1,默认波特率为 9600,8,n,1。
1. 读取数据 ( 功能码 0x03)
    问询帧(十六进制),发送举例:查询1#设备1个数据,上位机发送命令:01 03 00 00 00 A0 45 B2 。
地址功能码起始地址 数据长度 校验码
010300 0000 A045 B2
    对于正确的问询帧,设备会响应数据:01 03 FA 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 81 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 38 2B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ,响应格式:
地址功能码长度...校验码0103 FA00 81 38 2B
    数据说明:命令中数据为十六进制,以数据1为例,00 79转为十进制数值为121,假设数据倍率为100,则真实值为121/100=1.21,其它以此类推。
2. 数据地址表
组态地址寄存器地址寄存器说明数据类型值范围
4010100 64型号编码读/写
0~655354010200 65测点总数读/写
1~204010300 66设备地址读/写
1~2494010400 67波特率读/写
0~64010500 68通讯模式读/写
1~44010600 69协议类型读/写
1~104010700 6A时间间隔读/写
0~36000